Home > Support > Knowledge Base

Knowledge Base

All
Configuration: 15 result(s) found
Installation: 15 result(s) found
Hardware: 3 result(s) found
Miscellaneous: 14 result(s) found
Troubleshooting: 20 result(s) found

 

There are 34 search results for ""
What is the Non Operating (storage) temperature for Digi products?
Category: Configuration, Installation, Miscellaneous, Troubleshooting
Non Operating (Storage) Temperature is -40C to 80C (-40F to 150F) Non Operating (Storage) Humidity is 5 to 95% (non-condensing)
SuSE 8.2 RealPort Installation Instructions
Category: Installation
Preparing for the Installation: In SuSE 8.2, we had to download and install the following kernel and kernel source: ftp.suse.com/pub/suse/i386/8.2/suse/i586/kernel-source-2.4.20.SuSE-62.i586.rpm ftp://ftp.suse.com/pub/suse/i386/8.2/suse/i586/k_d...
Where can additional documentation regarding NET+OS be obtained?
Category: Miscellaneous
The Connect product line runs off of the NET+OS operating system which is built on top of ThreadX. The OS core is closed source, however, the source to most of the device drivers are provided, such as serial, Ethernet. Additional documentation on T...
EIA-232 Information
Category: Hardware
DTE vs DCE This is one of the most misunderstood areas of RS-232. DTE stands for Data Terminal Equipment, and DCE stands for Data Circuit-terminating Equipment or Data Communications Equipment. The DTE is typicall...
Recommended Custom Cable Vendors
Category: Miscellaneous
The Whyte Haus 260-484-5666 the.whytehaus@verizon.net Contact: Barb Whyte   Predator Grizzly Cable (503)292-7151 x 1101 CSP, Inc. 763-475-8346 mrannals@csp.com ...
Where can I locate Legacy drivers?
Category: Miscellaneous, Configuration, Hardware, Installation, Troubleshooting
Please visit the following page ftp://digiftp.digi.com/support_archive
The session configuration made when using GDBTK is not being maintained between uses of the tool.
Category: Installation, Troubleshooting
This most likely due to the directory specified by the environmental variable HOME not existing or being inaccessible (network login, etc.). There are a few paths one can take correct this problem. If the specified path does exist and is simply unre...
Discovering Digi devices under Windows XP Service Pack 2
Category: Configuration, Installation, Troubleshooting
Trouble discovering a Digi device using Windows XP with Service Pack 2?You will need to make sure that the Windows Firewall is disabled. By default it is enabled and will block the port that the discovery software uses to discover Digi. To disable th...
What is Digi International doing to comply with the RoHS requirements?
Category: Miscellaneous
Digi International is in the process of preparing to meet the RoHS requiements. For details, please visit this link:  http://www.digi.com/aboutus/environment.jsp  
From where may I obtain updates to NET+Works GNU and GHS development toolkits?
Category: Installation, Miscellaneous
Updates to currently shipping versions of NET+Works can be downloaded from here. Please contact Digi/NetSilicon support if your particular version of NET+Works is not listed. Online support request forms are available on the Digi and NetSilicon sup...
When installing a Digi driver in SuSE Linux with 2.6.x kernels, a tainted kernel message is seen.
Category: Installation, Troubleshooting
As an extension to the mainline kernel, modules can be tagged as supported (directly by SUSE, or indirectly by a third party) or unsupported. Modules which are known to be flakey or for which SUSE does not have the necessary expertise are marked as u...
MODPOST and module errors are seen when compiling the Digi driver with a new kernel on SuSE.
Category: Installation, Troubleshooting
Before SUSE''''''''s kernel sources are usable, you must issue the following commands: cd /usr/src/linux-2.6.8-24.14 make cloneconfig && make modules_prepare Otherwise kernel sources are not usable for building modules for your running kerne...
The end of my print jobs are being cut-off and never print the end of the document.
Category: Configuration, Troubleshooting
This behavior is due to the spooler closing the connection prior to the port buffer draining. The following command can be used to hold the port open so all of the data prints: # cat /dev/null & Where ttyx## represents the actual tty ...
How can I remotely manage dumb terminals attached to Digi Ethernet devices?
Category: Configuration, Miscellaneous
If you are using the network-enabled Digi products, they actually have some ability to monitor data directly, and other options may be available in addition to these suggestions. Some tools that are available if you want to implement your own so...
There is a very long delay seeing the login prompt in Solaris and UnixWare.
Category: Configuration, Troubleshooting
Customers have reported problems with ttymon handling a large amount of ports. Reportedly, adding more ttymons and only assigning 2 or 3 ports per ttymon relieves the symptoms.
When logging into an attached terminal, the session is returned back to a login within 30 seconds or before the password is entered.
Category: Configuration, Troubleshooting
Be sure to use the -L flag for agetty entries in the /etc/inittab file. This flag ignores DCD (carrier), in the event it is not wired on the cable.
How to send and receive raw LAN packets with NET+OS.
Category: Configuration
How to Send or Receive Raw LAN Packets in NET+OS INTRODUCTIONThis document describes how to send or receive raw LAN packets in the NET+OS Operating System. TOOLS NEEDEDPC or laptopNET+OS Operating SystemDigi Connect Product (ME, WiME, EM, WiEM, SP...
What does the RealPort WAN link setting do?
Category: Configuration, Troubleshooting
The WAN link setting limits the amount of data sent per second from the RealPort driver to the Digi Ethernet device. When fabricating packets in the driver to send to the Digi unit, ep a running count is kept of how much data to send, along with...
Can the time required for a Connect device to boot up be reduced?
Category: Configuration, Miscellaneous, Troubleshooting
It is possible to reduce the boot up time, of a Digi Connect device to just a few seconds, versus the default 20-40 seconds.Below are several modifications that can be made to the BSP. The net result of which, using the naftpa...
I am seeing random characters or garbage on the screen using SCO OpenServer 5. This is only seen within our Application.
Category: Configuration, Troubleshooting
Certain applications that are more graphical may show these symptoms. Try deactivating the fastcook setting on the affected port(s): # ditty printer -fastcook /dev/ttyx## Then see if this resolves the random characters with the application. If ...
When configuring an Ethernet device using the RealPort driver in Linux, there is an error indicating that it is unable to register the node.
Category: Installation, Troubleshooting
This is commonly seen after a kernel upgrade has taken place that requires a newer compiler. Run these two commands for analysis: cat /proc/version gcc --version The reported version numbers for the kernel used and the gcc compiler on your system ...
Error seen when initializing the driver in Linux : kernel-module version mismatch /lib/modules/(VER)/misc/dgxx.o was compiled for kernel version (VER)custom while this kernel is version (VER)
Category: Installation, Troubleshooting
This error indicates that modifications have been made to the kernel adding the "custom" extraversion. Here are the steps to remove the "custom" extraversion: # cd /usr/src/linux # make clean # vi Makefile You do not have to use "vi", simply u...
When I try to tip to a port, I see the following error: tip: /dev/term/x: Permission denied all ports busy
Category: Miscellaneous, Troubleshooting
This message is typically seen if another process is running on the port. Confirm your serial terminal settings to see if the port is locked by ttymon. The easiest way to check this is via admintool. Type "admintool" from the Solaris root prompt. ...
In Solaris, catting a file to the printer device works however, when using the print spooler the print job spools, disappears and nothing prints on the printer.
Category: None
Solaris print spoolers require DCD to be asserted on the port. This is commonly seen when DCD is not wired on the cable (3 to 8 wire connections). To force carrier on the port without wiring it, simply issue the following command from the Solaris roo...
The /etc/inittab file is not keeping the changes for the Digi ports
Category: Configuration, Troubleshooting
The drpadmin calls the /etc/conf/bin/idmkinit program in SCO. This is the same call when rebuilding the kernel, and it asks whether you "Would like the environment rebuilt". This will remove the current /etc/inittab file, and rebuild it from the fi...
Upon boot up of a Linux host using RealPort, the following errors are seen: agetty /dev/ttynx## cannot open as standard input Resource temporarily unavailable init: Id "XX##" respawning too fast: disabled for 5 minute
Category: None
This is an indication that the getty is trying to start before the actual ports have been initialized on the network. Try adding a sleep a "sleep 10" in the /etc/rc.d/init.d/dgrp_daemon file. Add the sleep command at the 3rd line from the bottom: ...
CYGWIN HINTS AND SHORTCUTS
Category: Configuration, Installation, Miscellaneous, Troubleshooting
INTRODUCTIONThe purpose of this document is to describe some simple tricks that will make working in cygwin a little easier. It is not intended to explain every possible problem that may come up. It is just a simple list of things to simplify the dev...
TROUBLE LOADING NEW SMICNG KEY (SNMP)
Category: Installation, Miscellaneous, Troubleshooting
DIRECTIONS TO LOAD NEW SMICNG KEY This document assumes that you have a Digi Connect Development Kit and are running it on a windows machine. It also assumes that you have already obtained a new key after the 1 year...
Building my project seems to never finish. I am also using a CVS.
Category: Troubleshooting
This could be due to the time stamp on the project files. If they are ahead of the current date and time (i.e. in the future) this will cause Digi ESP to get stuck in an infinite loop checking the dependancies. This can be easily corrected by using t...
Can I install the Realport drivers from the command line?
Category: Configuration, Installation
INTRODUCTIONYes. From the command line, you can browse to the folder containing the Realport Driver files and type:setup /? This will display the command line options for the Realport driver.
Where can I find the CAD files for your embedded modules?
Category: Miscellaneous
We normally don't provide these. Please contact Digi Technical Support with further inquiries 952 912-3456 or www.digi.com/support  
Use of content from Digi manuals
Category: Miscellaneous
Content from Digi manuals may be used by our OEM customers in their own documentation subject to the following conditions: Clearly state: "Parts of this manual are used by permission of Digi, Inc." Submit a copy of the...
How to find out the date code and manufacturing location information of Digi Products.
Category: Configuration, Hardware, Installation, Miscellaneous
Depending on the location the units are built effects the orientation, linked below is the date code from USA or Thailand.  The date code is 4 digits, 2 digit year and 2 digit week (YYWW) so in these examples the 26th week of 2012. Thailand M...
Contact a Digi expert and get started today! CONTACT US