Support / Knowledge Base / Unable to access any ports above COM9 in Windows NT with an application.

Unable to access any ports above COM9 in Windows NT with an application.

Unable to access any ports above COM9 in Windows NT with an application.

Symptom:

I'm writing my own application and I am not able to access any ports above COM9.
 

Cause

In Windows NT, the ports above COM9 must be addressed with the following naming convention: .COM#

Solution

For example, COM10 should be addressed as .COM10.  You may also address COM1-9 with the same naming convention.  Windows NT will recognize either name.