Support / Knowledge Base / JTAG Link not working with older revision of development board

JTAG Link not working with older revision of development board

When using the Digi USB JTAG-Link see: https://www.digi.com/products/models/dg-acc-jlnk
with an older revision of the Digi Connect (Wi-)ME (9210) development board, you might experience failure messages:
Could not perform target reset
Failed to connect.
Could not perform custom init sequence.
User-added image

Known good development board has green silk screen number: 30006002-06 REV A
Known bad development board has green silk screen number: 30006002-05 REV A

fix: buy a new development board DC-ACC-DBME Revision E, 50000882-05 Revision D, 55001086-06 Revision A or newer